Maximum capacity(Emax) | 5t | |||||
Accuracy class | C3 | |||||
Approvals | OIML R60 C3 | |||||
Maximum number of load cell intervals(nLC) | 3000 | |||||
Ratio of minimum LC verification interval Y=Emax/Vmin | 10000 | |||||
Combined error | %FS | ±0.020 | ||||
Creep | %FS/30min | ±0.016 | ||||
Temperature effect on sensitivity | %FS/10ºC | ±0.011 | ||||
Temperature effect on zero | %FS/10ºC | ±0.015 | ||||
Output sensitivity(=FS) | mV/V | 3±0.003 2.0±0.002 | ||||
Input resistance | Ω | 350±3.5 | ||||
Onput resistance | Ω | 350±3.5 | ||||
Insulation resistance | MΩ | ≥5000(50VDC) | ||||
Zero balance | %FS | ±1.0 | ||||
Compensated temperature | ºC | -10~+40 | ||||
Operating temperature | ºC | -35~+70 | ||||
Excitation,recommended voltage | V | 5~12(DC) | ||||
Excitation maximum | V | 18(DC) | ||||
Safe overload | %FS | 150 | ||||
Ultimate overload | %FS | 300 | ||||
Recommended torque on fixation | N.m | M12: 100; M18: 200; M24: 700 | ||||
Ingress protection(according to EN 60529) | IP67 |